specProc processes and analyzes emission spectra, streamlining the pipeline from raw spectra to calibrated concentrations. While specifically developed for laser-induced breakdown spectroscopy (LIBS), it seamlessly supports other plasma techniques such as ICP-OES. Select functions can also be used to process Raman and infrared spectroscopy data. The package structures data with one spectrum per row and wavelengths as column names, leveraging a C++ backend to power heavy computations.
Install the released version from CRAN:
install.packages("specProc")or the development version from GitHub:
# install.packages("remotes")
remotes::install_github("ChristianGoueguel/specProc", build_vignettes = TRUE)A C++ compiler is needed to build the development version from source (Rtools on Windows, Xcode Command Line Tools on macOS).
The vignettes follow a typical LIBS analysis, on the
forageLIBS spectra of forage samples:
vignette("peak-fitting")): line identification, wavelength
calibration, line profiles and overlapping lines.vignette("preprocessing")): baseline correction,
normalization and other step_*() functions, in a tidymodels
workflow.vignette("calibration")): univariate curves, limits of
detection and quantification, and the net analyte signal of multivariate
models.vignette("plasma-diagnostics")): electron density,
temperature, LTE, self-absorption and calibration-free LIBS.They are also available as articles on the package website.
| Task | Functions |
|---|---|
| Line identification | libs_lines(), plot_lines(),
line_finder() (Shiny app, with an interactive Boltzmann
plot), molecular_bands(),
molecular_spectrum(),
wavelength_calibration(), apply_calibration(),
response_calibration(),
correct_response() |
| Line fitting | peak_fit(), multipeak_fit(),
plot_fit(), line_intensities(),
voigt_profile(), pseudo_voigt_profile(),
gaussian_profile(), lorentzian_profile(),
voigt_fwhm(), doppler_width() |
| Preprocessing | baseline_arpls(), baseline_als(),
baseline_lsp(), snv(), msc(),
emsc(), normalize(),
savitzky_golay(), wavelet_denoise(),
gap_derivative(), bin_spectra(),
wavelet_features(), reject_shots(),
average() |
| Recipe steps | step_baseline(), step_snv(),
step_msc(), step_emsc(),
step_spectral_norm(), step_line_ratio(),
step_savgol(), step_wavelet_denoise(),
step_gap_derivative(), step_bin_spectra(),
step_wavelet(), step_line_intensities(),
step_reject_shots(), step_opls(),
step_o2pls(), step_epo(),
step_glsw(), and more |
| Orthogonalization | osc(), direct_osc(),
projected_osc(), opls(), o2pls(),
epo(), glsw(),
y_gradient_glsw() |
| Calibration | calibration_curve() (least squares, Deming, York; ICH
or ISO 11843 limits), plot_calibration(),
nas(), pds(), ds(),
sst(), slope_bias(),
applicability_domain(), control_chart() |
| Wavelength selection and robust calibration | select_wavelengths(),
plot_wavelength_selection(),
step_select_wavelengths(), rsimpls(),
step_rsimpls(), rpcr(),
robust_rmsecv(), the "rsimpls" engine of
parsnip::pls() and "lts" engine of
parsnip::linear_reg() |
| Robust classification | rsimca(), plot_coomans(),
robust_da(), the simca() parsnip model, the
"mcd" engines of parsnip::discrim_linear() and
parsnip::discrim_quad() |
| Plasma diagnostics | saturation_summary(), electron_density(),
boltzmann(), saha_boltzmann(),
plot_boltzmann(), plasma_uncertainty(),
electron_density_uncertainty(),
mcwhirter_criterion(), lte_criteria(),
self_absorption(), correct_self_absorption(),
curve_of_growth(), cf_libs(),
nist_lines(), starkb_lines() |
| Outliers and robust PCA | robpca(), rospca(),
macropca(), cellpca(),
plot_outlier_map(), plot_cell_map(),
q_residuals(), dmodx(),
plot_influence(), hotelling_t2() |
| Robust statistics | summary_stats(), biweight_location(),
biweight_scale(), rousseeuw_croux(),
umad(), adjusted_boxplot(),
medcouple(), robust_boxcox(),
robust_yeojohnson(), robust_gandh() |
| Tidy results | tidy() and glance() of peak fits,
calibrations, plasma diagnostics and chemometric models |
| Visualization | plot_spectra(), plot_embedding(),
plot_loadings(), plot_contributions() |
See the reference for the full list.
Which preprocessing and which model suit a LIBS calibration is an
empirical question. Since every specProc step is a recipe step,
candidate pipelines can be compared on an equal footing: each recipe is
re-estimated in every resample, together with the model. Here we predict
calcium from all 368 forageLIBS spectra. Calcium has strong
lines in these spectra (Ca II 393.37 and 396.85 nm, Ca I 422.67 nm), a
laboratory value for every sample, and a calibration error that reaches
its minimum within a few components, so the trade-offs are easy to
see.
data("forageLIBS")
spectra_id <- c("Measurement", "Sample")
minerals <- names(forageLIBS)[3:14]per_spectrum <- \(data, step, ...) {
recipe(~ ., data = data) |>
update_role(all_of(c(spectra_id, minerals)), new_role = "id") |>
step(all_predictors(), ...) |>
prep() |>
bake(new_data = NULL)
}corrected <- per_spectrum(forageLIBS, step_baseline, lambda = 1e5, options = list(max_iter = 20))
area <- per_spectrum(corrected, step_spectral_norm, method = "area")
carbon <- per_spectrum(corrected, step_line_ratio, reference = 247.856, window = 0.15)
compressed <- per_spectrum(carbon, step_wavelet, level = 3)ca_recipe <- \(data) {
recipe(Ca ~ ., data = data) |>
update_role(all_of(spectra_id), all_of(setdiff(minerals, "Ca")), new_role = "id")
}The baseline is removed in every pipeline. The steps estimated from
the training data (principal components, orthogonal filter, selected
wavelengths) and the model parameters are tuned together. Wavelength
selection (step_select_wavelengths()) keeps the channels
with the largest variable importance in projection (VIP) or selectivity
ratio (SR) in a PLS model, or, with interval PLS (iPLS), the contiguous
intervals (out of 40) that lower the cross-validated error of a PLS
model; the number of channels or intervals is tuned with the
components:
# mixOmics scales every predictor by default; scale = FALSE only centers
pls_model <- pls(num_comp = tune()) |> set_mode("regression") |> set_engine("mixOmics", scale = FALSE)
pcr_model <- linear_reg() |> set_engine("lm")
enet_model <- linear_reg(penalty = tune(), mixture = tune()) |> set_engine("glmnet")
svr_model <- svm_rbf(cost = tune(), rbf_sigma = tune()) |> set_mode("regression") |> set_engine("kernlab")components <- tibble(num_comp = 1:20)
pipelines <- list(
"PLS" = list(ca_recipe(corrected), pls_model, components),
"Area + PLS" = list(ca_recipe(area), pls_model, components),
"C I + PLS" = list(ca_recipe(carbon), pls_model, components),
"C I + iPLS + PLS" = list(ca_recipe(carbon) |> step_select_wavelengths(all_predictors(), method = "ipls", num_intervals = tune(), num_comp = 10), pls_model, expand_grid(components, num_intervals = c(2L, 4L, 6L, 8L))),
"C I + VIP + PLS" = list(ca_recipe(carbon) |> step_select_wavelengths(all_predictors(), method = "vip", num_terms = tune()), pls_model, expand_grid(components, num_terms = c(100L, 300L, 1000L, 3000L))),
"C I + SR + PLS" = list(ca_recipe(carbon) |> step_select_wavelengths(all_predictors(), method = "sr", num_terms = tune()), pls_model, expand_grid(components, num_terms = c(100L, 300L, 1000L, 3000L))),
"C I + wavelet + PLS" = list(ca_recipe(compressed), pls_model, components),
"C I + wavelet + PCR" = list(ca_recipe(compressed) |> step_center(all_predictors()) |> step_pca(all_predictors(), num_comp = tune()), pcr_model, components),
"C I + wavelet + robust PCR" = list(ca_recipe(compressed) |> step_robpca(all_predictors(), num_comp = tune(), options = list(ncomp_max = 20)), pcr_model, components),
"C I + wavelet + OPLS + enet" = list(ca_recipe(compressed) |> step_opls(all_predictors(), num_comp = tune()), enet_model, expand_grid(num_comp = 1:4, penalty = 10^seq(-4, -1, by = 0.5), mixture = c(0.1, 0.5, 1))),
"C I + wavelet + SVR" = list(ca_recipe(compressed), svr_model,expand_grid(cost = 2^seq(0, 8, by = 2), rbf_sigma = 10^seq(-4.5, -2.5, by = 0.5)))
)Each pipeline is cross-validated in five repeats of a 5-fold split that keeps the spectra of a sample in the same fold. The 25 resamples are spread over parallel workers with the future package; tune gives each resample the same random numbers in parallel as in sequence, so the results do not depend on the number of workers:
cv_folds <- \(data) {
set.seed(2026)
group_vfold_cv(data, group = Sample, v = 5, repeats = 5)
}future::plan("multisession", workers = parallelly::availableCores(omit = 1))
results <- map(pipelines, \(p) {
rec <- p[[1]]
tune_grid(
workflow(rec, p[[2]]),
resamples = cv_folds(rec$template),
grid = p[[3]],
metrics = metric_set(rmse, rsq),
control = control_grid(save_pred = TRUE)
)
})
future::plan("sequential")The cross-validated RMSE of the component-based pipelines as a function of the number of components: on the left, the normalizations; in the middle, the models of the wavelet coefficients, with the best elastic net and SVR models (on the same coefficients) as references; on the right, the wavelength selections, each with its best number of channels or intervals, and PLS on all the channels (grey) as reference:

All pipelines are evaluated on the same 25 splits, so they can be compared split by split, here with C I + PLS. Since the resamples overlap, the standard error of the mean difference is inflated as in the corrected repeated k-fold test (Nadeau and Bengio, 2003; Bouckaert and Frank, 2004):

Contrasts between preprocessing steps and models:
| Contrast | Mean difference (% Ca) | Splits where the first is better | p (corrected) |
|---|---|---|---|
| C I + PLS vs PLS | -0.0019 | 20 / 25 | 0.24 |
| Area + PLS vs PLS | 0.0018 | 8 / 25 | 0.40 |
| C I + iPLS + PLS vs C I + PLS | 0.0001 | 12 / 25 | 0.95 |
| C I + VIP + PLS vs C I + PLS | 0.0000 | 16 / 25 | 0.67 |
| C I + SR + PLS vs C I + PLS | -0.0002 | 16 / 25 | 0.91 |
| C I + wavelet + PLS vs C I + PLS | 0.0001 | 12 / 25 | 0.96 |
| C I + wavelet + SVR vs C I + wavelet + PLS | 0.0035 | 5 / 25 | 0.36 |
If you use specProc in a publication, please cite it. In R,
citation("specProc") gives the reference of the installed
version:
Goueguel, C. L. (2026). specProc: Analysis of Laser-Induced Breakdown Spectroscopy Data. R package version 0.9.0. https://github.com/ChristianGoueguel/specProc
A BibTeX entry for LaTeX users:
@Manual{specProc,
title = {{specProc}: Analysis of Laser-Induced Breakdown Spectroscopy Data},
author = {Christian L. Goueguel},
year = {2026},
note = {R package version 0.9.0},
url = {https://github.com/ChristianGoueguel/specProc},
}Replace the version and year with those of the version you used
(packageVersion("specProc")). Please also cite the original
papers of the methods you use, listed in the References section of their
help pages (for example, ?robpca or
?rsimpls).
MIT © Christian L. Goueguel