| psychrolib-package | PsychroLib: Psychrometric Properties of Moist and Dry Air |
| CalcPsychrometricsFromRelHum | Calculate psychrometric values from relative humidity. |
| CalcPsychrometricsFromTDewPoint | Calculate psychrometric values from dew-point temperature. |
| CalcPsychrometricsFromTWetBulb | Calculate psychrometric values from wet-bulb temperature. |
| GetDegreeOfSaturation | Return the degree of saturation (i.e humidity ratio of the air / humidity ratio of the air at saturation at the same temperature and pressure) given dry-bulb temperature, humidity ratio, and atmospheric pressure. |
| GetDryAirDensity | Return dry-air density given dry-bulb temperature and pressure. |
| GetDryAirEnthalpy | Return dry-air enthalpy given dry-bulb temperature. |
| GetDryAirVolume | Return dry-air volume given dry-bulb temperature and pressure. |
| GetHumRatioFromEnthalpyAndTDryBulb | Return humidity ratio from enthalpy and dry-bulb temperature. |
| GetHumRatioFromRelHum | Return humidity ratio given dry-bulb temperature, relative humidity, and pressure. |
| GetHumRatioFromSpecificHum | Return the humidity ratio (aka mixing ratio) from specific humidity. |
| GetHumRatioFromTDewPoint | Return humidity ratio given dew-point temperature and pressure. |
| GetHumRatioFromTWetBulb | Return humidity ratio given dry-bulb temperature, wet-bulb temperature, and pressure. |
| GetHumRatioFromVapPres | Return humidity ratio given water vapor pressure and atmospheric pressure. |
| GetMoistAirDensity | Return moist air density given humidity ratio, dry bulb temperature, and pressure. |
| GetMoistAirEnthalpy | Return moist air enthalpy given dry-bulb temperature and humidity ratio. |
| GetMoistAirVolume | Return moist air specific volume given dry-bulb temperature, humidity ratio, and pressure. |
| GetRelHumFromHumRatio | Return relative humidity given dry-bulb temperature, humidity ratio, and pressure. |
| GetRelHumFromTDewPoint | Return relative humidity given dry-bulb temperature and dew-point temperature. |
| GetRelHumFromTWetBulb | Return relative humidity given dry-bulb temperature, wet bulb temperature and pressure. |
| GetRelHumFromVapPres | Return relative humidity given dry-bulb temperature and vapor pressure. |
| GetSatAirEnthalpy | Return saturated air enthalpy given dry-bulb temperature and pressure. |
| GetSatHumRatio | Return humidity ratio of saturated air given dry-bulb temperature and pressure. |
| GetSatVapPres | Return saturation vapor pressure given dry-bulb temperature. |
| GetSeaLevelPressure | Return sea level pressure given dry-bulb temperature, altitude above sea level and pressure. |
| GetSpecificHumFromHumRatio | Return the specific humidity from humidity ratio (aka mixing ratio). |
| GetStandardAtmPressure | Return standard atmosphere barometric pressure, given the elevation (altitude). |
| GetStandardAtmTemperature | Return standard atmosphere temperature, given the elevation (altitude). |
| GetStationPressure | Return station pressure from sea level pressure. |
| GetTCelsiusFromTKelvin | Utility function to convert temperature to degree Celsius (degreeC) given temperature in Kelvin (K). |
| GetTDewPointFromHumRatio | Return dew-point temperature given dry-bulb temperature, humidity ratio, and pressure. |
| GetTDewPointFromRelHum | Return dew-point temperature given dry-bulb temperature and relative humidity. |
| GetTDewPointFromTWetBulb | Return dew-point temperature given dry-bulb temperature, wet-bulb temperature, and pressure. |
| GetTDewPointFromVapPres | Return dew-point temperature given dry-bulb temperature and vapor pressure. |
| GetTDryBulbFromEnthalpyAndHumRatio | Return dry bulb temperature from enthalpy and humidity ratio. |
| GetTDryBulbFromMoistAirVolumeAndHumRatio | Return dry-bulb temperature given moist air specific volume, humidity ratio, and pressure. |
| GetTFahrenheitFromTRankine | Utility function to convert temperature to degree Fahrenheit (degreeF) given temperature in degree Rankine (degreeR). |
| GetTKelvinFromTCelsius | Utility function to convert temperature to Kelvin (K) given temperature in degree Celsius (degreeC). |
| GetTRankineFromTFahrenheit | Utility function to convert temperature to degree Rankine (degreeR) given temperature in degree Fahrenheit (degreeF). |
| GetTWetBulbFromHumRatio | Return wet-bulb temperature given dry-bulb temperature, humidity ratio, and pressure. |
| GetTWetBulbFromRelHum | Return wet-bulb temperature given dry-bulb temperature, relative humidity, and pressure. |
| GetTWetBulbFromTDewPoint | Return wet-bulb temperature given dry-bulb temperature, dew-point temperature, and pressure. |
| GetUnitSystem | Return system of units in use. |
| GetVaporPressureDeficit | Return Vapor pressure deficit given dry-bulb temperature, humidity ratio, and pressure. |
| GetVapPresFromHumRatio | Return vapor pressure given humidity ratio and pressure. |
| GetVapPresFromRelHum | Return partial pressure of water vapor as a function of relative humidity and temperature. |
| GetVapPresFromTDewPoint | Return vapor pressure given dew point temperature. |
| isIP | Check whether the system in use is IP or SI. |
| psychrolib | PsychroLib: Psychrometric Properties of Moist and Dry Air |
| SetUnitSystem | Set the system of units to use (SI or IP). |