| Type: | Package | 
| Title: | Functional MRI Quality Assurance Routines | 
| Version: | 0.3.0 | 
| Date: | 2018-02-19 | 
| Description: | Methods for performing fMRI quality assurance (QA) measurements of test objects. Heavily based on the fBIRN procedures detailed by Friedman and Glover (2006) <doi:10.1002/jmri.20583>. | 
| BugReports: | https://github.com/martin3141/fmriqa/issues | 
| License: | GPL-3 | 
| LazyData: | true | 
| RoxygenNote: | 6.0.1 | 
| Imports: | viridisLite, RNifti, ggplot2, reshape2, gridExtra, grid, tidyr, optparse, tcltk, RcppEigen, imager, pracma | 
| Encoding: | UTF-8 | 
| Suggests: | testthat, covr, knitr, rmarkdown | 
| VignetteBuilder: | knitr | 
| NeedsCompilation: | no | 
| Packaged: | 2018-02-19 12:33:39 UTC; wilsonmp | 
| Author: | Martin Wilson [cre, aut] | 
| Maintainer: | Martin Wilson <martin@pipegrep.co.uk> | 
| Repository: | CRAN | 
| Date/Publication: | 2018-02-19 15:59:01 UTC | 
fmriqa: fMRI quality assurance routines
Description
The fmriqa package provides an implementation of the fMRI quality assurance analysis protocol detailed by Friedman and Glover (2006) <doi:10.1002/jmri.20583>.
Details
#' To learn more about fmriqa, start with the vignettes: 'browseVignettes(package = "fmriqa")'
For a full list of functions: 'help(package=fmriqa, help_type="html")'
Author(s)
Maintainer: Martin Wilson martin@pipegrep.co.uk
See Also
Useful links:
Report bugs at https://github.com/martin3141/fmriqa/issues
Run fMRI quality assurance procedure on a NIfTI data file
Description
Run fMRI quality assurance procedure on a NIfTI data file
Usage
run_fmriqa(data_file = NULL, roi_width = 21, slice_num = NULL, skip = 2,
  tr = NULL, pix_dim = NULL, poly_det_ord = 3, spike_detect = FALSE,
  x_pos = NULL, y_pos = NULL, plot_title = NULL, last_vol = NULL,
  gen_png = TRUE, gen_res_csv = TRUE, gen_pdf = FALSE,
  gen_spec_csv = FALSE, png_fname = NULL, res_fname = NULL,
  pdf_fname = NULL, spec_fname = NULL, verbose = TRUE, bg_smooth = 12,
  bg_shrink = 25)
Arguments
data_file | 
 input data in nifti format, a file chooser will open if not set  | 
roi_width | 
 roi analysis region in pixels (default=21)  | 
slice_num | 
 slice number for analysis (default=middle slice)  | 
skip | 
 number of initial volumes to exclude from the analysis (default=2)  | 
tr | 
 override the TR detected from data (seconds)  | 
pix_dim | 
 override the x,y,z pixel dimensions (mm) detected from data eg pixdim=c(3,3,3)  | 
poly_det_ord | 
 polynomial order used for detrending (default=3)  | 
spike_detect | 
 generate k-space spike-detection plot (default=FALSE)  | 
x_pos | 
 x position of ROI (default=center of gravity)  | 
y_pos | 
 y position of ROI (default=center of gravity)  | 
plot_title | 
 add a title to the png and pdf plots  | 
last_vol | 
 last volume number to use in the analysis  | 
gen_png | 
 output png plot (default=TRUE)  | 
gen_res_csv | 
 output csv results (default=TRUE)  | 
gen_pdf | 
 output pdf plot (default=FALSE)  | 
gen_spec_csv | 
 output csv of spectral points (default=FALSE)  | 
png_fname | 
 png plot filename  | 
res_fname | 
 csv results filename  | 
pdf_fname | 
 pdf plot filename  | 
spec_fname | 
 csv spectral data filename  | 
verbose | 
 provide text output while running (default=TRUE)  | 
bg_smooth | 
 amount to smooth background image before calculating the maximum BG percent metric (default=12mm)  | 
bg_shrink | 
 amount to shrink the BG image away from the object to avoid residual object signal in the maximum BG percent metric (default=25mm)  | 
Value
dataframe of QA metrics
Examples
fname <- system.file("extdata", "qa_data.nii.gz", package = "fmriqa")
res <- run_fmriqa(data_file = fname, gen_png = FALSE, gen_res_csv = FALSE, tr = 3)